Abstract

BackgroundAccurate diagnosis of urogenital schistosomiasis is vital for surveillance/control programs. Amplification of schistosome DNA in urine by PCR is sensitive and specific but requires infrastructure, financial resources and skilled personnel, often not available in endemic areas. Recombinase Polymerase Amplification (RPA) is an isothermal DNA amplification/detection technology that is simple, rapid, portable and needs few resources.FindingsHere a Schistosoma haematobium RPA assay was developed and adapted so that DNA amplicons could be detected using oligochromatographic Lateral Flow (LF) strips. The assay successfully amplified S. haematobium DNA at 30–45 °C in 10 mins and was sensitive to a lower limit of 100 fg of DNA. The assay was also successful with the addition of crude urine, up to 5 % of the total reaction volume. Cross amplification occurred with other schistosome species but not with other common urine microorganisms.ConclusionThe LF-RPA assay developed here can amplify and detect low levels of S. haematobium DNA. Reactions are rapid, require low temperatures and positive reactions are interpreted using lateral flow strips, reducing the need for infrastructure and resources. This together with an ability to withstand inhibitors within urine makes RPA a promising technology for further development as a molecular diagnostic tool for urogenital schistosomiasis.

Highlights

  • Accurate diagnosis of urogenital schistosomiasis is vital for surveillance/control programs

  • Hematuria, bladder wall pathology, hydronephrosis leading to severe kidney disease [1, 2] and bladder cancer [3]; in addition, an estimated 16 million women suffer from female genital schistosomiasis (FGS), which can cause complications in relation to fertility and HIV transmission [4]

  • Sensitive and specific diagnostic tests are critical for the development and success of schistosomiasis control and elimination programs

Read more

Summary

Conclusion

The LF-RPA assay developed here can amplify and detect low levels of S. haematobium DNA. Require low temperatures and positive reactions are interpreted using lateral flow strips, reducing the need for infrastructure and resources. This together with an ability to withstand inhibitors within urine makes RPA a promising technology for further development as a molecular diagnostic tool for urogenital schistosomiasis

Introduction
B Control line
Discussion
A Control line
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call