Abstract
An isolating method using a solid-phase extraction (SPE) ISOLUTE® C8 endcapped syringe-column for routine monitoring of residual tetracyclines (TCs) (oxytetracycline (OTC), tetracycline (TC), chlortetracycline (CTC), and doxycycline (DC)) in cow's milk is presented. In the simplest and most environmentally harmless method, milk samples could be applied directly to the SPE column, following which all TCs were eluted with water. No organic solvents were used at all. The purified sample was injected into a high-performance liquid chromatography (HPLC) with a photo-diode array detector (PDAD). For the HPLC determination/identification, a LiChrospher® 100 RP-8 endcapped column and a mobile phase of acetonitrile −7% (v v −1) acetic acid solution (in water) (35:65, v v −1) with a PDAD was used. The total time required for the analysis of one sample was <40 min. Average recoveries (spiked 0.1–1.0 μg ml −1 each drug) and their standard deviations were >80 and <5%, respectively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.