Abstract

PurposeTo investigate the isodose surface volumes (ISVs) for 85, 75 and 60 Gy EQD2 for locally advanced cervix cancer patients. Materials and methods1201 patients accrued in the EMBRACE I study were analysed. External beam radiotherapy (EBRT) with concomitant chemotherapy was followed by MR based image-guided adaptive brachytherapy (MR-IGABT). ISVs were calculated using a predictive model based on Total Reference Air Kerma and compared to Point A-standard loading systems. Influence of fractionation schemes and dose rates was evaluated through comparison of ISVs for α/β 10 Gy and 3 Gy. ResultsMedian V85 Gy, V75 Gy and V60 Gy EQD210 were 72 cm3, 100 cm3 and 233 cm3, respectively. Median V85 Gy EQD210 was 23% smaller than in standard 85 Gy prescription to Point A. For small (<25 cm3), intermediate (25–35 cm3) and large (>35 cm3) CTVHR volumes, the V85 Gy was 57 cm3, 70 cm3 and 89 cm3, respectively. In 38% of EMBRACE patients the V85 Gy was similar to standard plans with 75–85 Gy to Point A. 41% of patients had V85 Gy smaller than standard plans receiving 75 Gy at Point A, while 21% of patients had V85 Gy larger than standard plans receiving 85 Gy at Point A. ConclusionsMR-IGABT and individualized dose prescription during EMBRACE I resulted in improved target dose coverage and decreased ISVs compared to standard plans used with classical Point A based brachytherapy. The ISVs depended strongly on CTVHR volume which demonstrates that dose adaptation was performed per individual tumour size and response during EBRT.