Abstract
Percutaneous radial artery cannulation is commonly used for continuous monitoring of blood pressure and estimation of arterial blood gases. The purpose of this study is to define the incidence of radial artery thrombosis and associated hand ischaemia after cannulation. A prospective study of 40 patients who underwent radial artery cannulation was carried out with patients examined before and after cannulation for radial and ulnar pulses. Doppler waveforms, and Anger/brachial and finger/wrist pressure indices were obtained. After cannulation 27.5% of patients developed abnormal radial artery flows with 10% having absent pulses and none having any symptoms of hand ischaemia. Radial artery cannulation is a safe procedure when performed properly and is associated with a very low incidence of hand ischaemia, despite a 27.5% incidence of abnormal radial artery flow after cannulation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.