Abstract

The objective of our study was to evaluate the accuracy of true fast imaging with steady-state precession (FISP) in the diagnosis of venous thrombosis using gadolinium-enhanced 3D T1-weighted gradient-echo images and correlative imaging as the gold standard. Twenty-five MR examinations were retrospectively reviewed independently by two radiologists to rule out thrombosis in the central veins of the body. The presence of venous thrombus was assessed separately in 80 veins using true FISP and gadolinium-enhanced T1-weighted images. Diagnosis was confirmed by another imaging technique (sonography, CT, and/or conventional venography) in all positive cases. Negative examinations were confirmed using imaging, clinical follow-up, or both. Venous thrombosis was present in 25 veins in 18 patients. True FISP images had a lower sensitivity (66%) and specificity (70.9%) for the diagnosis of venous thrombosis than gadolinium-enhanced MR images (p < 0.01). True FISP images have lower sensitivity and specificity in the diagnosis of venous thrombosis than gadolinium-enhanced T1-weighted gradient-echo images. True FISP images should not be used exclusively for the diagnosis of venous thrombosis.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call