Abstract

AimsTo investigate the potential role for a biological boost in anal cancer by assessing whether subvolumes of high 18F-fluorodeoxyglucose (FDG) avidity, identified at outset, are spatially consistent during a course of chemoradiotherapy (CRT). Materials and methodsFDG-positron emission tomography (FDG-PET) scans from 21 patients enrolled into the ART study (NCT02145416) were retrospectively analysed. In total, 29 volumes including both primary tumours and involved nodes >2 cm were identified. FDG-PET scans were carried out before treatment and on day 8 or 9 of CRT. FDG subvolumes were created using a percentage of maximum FDG avidity at thresholds of 34%, 40%, 50%, on the pre-treatment scans, and 70% and 80% on the subsequent scans. Both FDG-PET scans were deformably registered to the planning computed tomography scan. The overlap fraction and the vector distance were calculated to assess spatial consistency. FDG subvolumes for further investigation had an overlap fraction >0.7, as this has been defined in previous publications as a ‘good’ correlation. ResultsThe median overlap fractions between the diagnostic FDG-PET subvolumes 34%, 40% and 50% of maximum standardised uptake value (SUVmax) and subsequent FDG-PET subvolumes of 70% of SUVmax were 0.97, 0.92 and 0.81. The median overlap fraction between the diagnostic FDG-PET subvolumes 34%, 40% and 50% and subsequent FDG-PET subvolumes of 80% were 1.00, 1.00 and 0.92. The median (range) vector distance values between diagnostic FDG-PET subvolumes 34%, 40% and 50% and subsequent FDG-PET subvolumes of 80% were 0.74 mm (0.19–2.94) 0.74 mm (0.19–3.39) and 0.71 mm (0.2–3.29), respectively. Twenty of 29 volumes (69.0%) achieved a threshold > 0.7 between the FDG 50% subvolume on the diagnostic scan and the FDG 80% subvolume on the subsequent scan. ConclusionFDG-avid subvolumes identified at baseline were spatially consistent during a course of CRT treatment. The subvolume of 50% of SUVmax on the pre-treatment scan could be considered as a potential target for dose escalation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.