Abstract

Background Prolonged use of mechanical ventilation is associated with some complications as high mortality and high morbidities as bronchopulmonary dysplasia, ventilator-associated pneumonia, and pneumothorax. However, extubation failure in preterm infants is still high (40–60%) in very low birth weight infants (VLBW). Noninvasive neurally adjusted ventilatory assistance (NIV-NAVA) is triggered by the diaphragmatic electrical activity through a nasogastric tube that synchronizes patient/ventilator respiration, cycle by cycle effectively shortening the assisted cycle trigger and the degree of ventilatory assistance, optimizing the effects of intermittent inspiratory pressure on nasal continuous positive airway pressure (NCPAP). This study aims to compare reintubation rates until 72 h after extubation in preterm infants of high risk for reintubation using NIV-NAVA or NCPAP. Methods A retrospective study of chart review data collection was performed in a private tertiary hospital. The study was approved by the local institutional Ethics Committee. We included infants considered at high risk of reintubation (BW < 1000 grams; use of invasive mechanical ventilation (IMV) for at least 7 days; or previous extubation failure episode) and compared the two groups according to the type of respiratory support after extubation: (1) NCPAP (n = 32); or (2) NIV-NAVA (n = 17). Demographics data were collected, the primary outcome was reintubation rate until 72 h after extubation. Secondary outcome was time to reintubation, BPD rate, IVH grade ≥ III, pneumothorax and death. Results There was no difference between both groups in demographic data. The reintubation rate decreased significantly in the NIV-NAVA group compared to NCPAP (50.0–11.7, p < .02) despite the significantly higher length of invasive mechanical ventilation (IMV) before extubation attempt in NIV-NAVA group (12.4 versus 5.5 days, p < .04). There was no difference between both groups in secondary outcomes. Conclusions In this small retrospective cohort study, the use of NIV-NAVA as postextubation strategy was effective in reducing extubation failure within 72 h in preterm infants when compared to traditional NCPAP.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call