Abstract

Background: The aim of this study was to compare setup accuracy and reproducibility of a stereotactic head and a head-and-neck fixation system, both based on thermoplastic material. Methods and Material: Ten patients were immobilized with a head and a head-and-neck fixation system (both BrainLAB, Germany). Both mask systems were modified with a custom-made mouthpiece and a strip of thermoplastic material attached to the lower part of the mask. During the first treatment session, after positioning patients using room lasers, two orthogonal portal images were taken as reference. Later on, at least five sets of orthogonal portal images were acquired for each patient. The isocentric setup accuracy was determined by comparing field edges and anatomic landmarks and the repositioning accuracy in the mask was obtained by comparing individual anatomic landmarks with respect to the metal balls, fixed on the masks. Systematic and random deviations and resulting three-dimensional (3D) vectors were calculated. Additionally, margins were derived from the systematic and random component of the isocentric setup accuracy. Finally, inter- and intraobserver variations were analyzed. Results: The systematic variation of the isocentric setup accuracy was very similar for the two mask systems, but the random variations were slightly larger for the head-and-neck system, resulting in a 0.4-mm larger 3D vector. The repositioning variations for the head mask were smaller compared with the head-and-neck mask, resulting in smaller 3D vectors for the random (∼0.4 mm) and systematic variations (∼0.6 mm). For both mask systems, a 2-mm margin can be used in lateral and anteroposterior direction, whereas in craniocaudal direction, this margin should be extended to 2.5 mm for the head mask and to 3 mm for the head-and-neck mask. The average absolute differences between two observers were within 0.5 mm, maximum deviations around 1 mm. Conclusion: Thermoplastic mask–based stereotactic head-and-neck fixation allows accurate and reproducible fixation of patients. For intensity-modulated radiation therapy in the upper head-and-neck region, the application of reduced margins around 2–3 mm, which has an implication on organ sparing, is enabled by such an immobilization device.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.