Abstract
A brief discontinuation (< 1 week) of long-term ventilation may be necessary in patients who are not totally ventilator-dependent in cases of technical problems, intolerable nasal irritation, upper airway congestion, or travel. We examined the incidence, timing, and causes of possible clinical deterioration after a brief withdrawal of ventilation in patients with chronic respiratory failure (CRF) who were well-established on long-term noninvasive mechanical ventilation (NIMV). Prospective clinical study. Eleven inpatients in clinically stable condition (COPD, 6 patients; and restrictive thoracic disease [RTD], 5 patients) who had severe CRF (PaCO(2), > 50 mm Hg) and had been receiving NIMV for (mean +/- SD) 19.3 +/- 5.3 months were enrolled. Arterial blood gas (ABG) levels, maximal inspiratory pressure (PImax), breathing pattern, dyspnea rating, and life symptoms (measured by a questionnaire) were recorded daily after NIMV withdrawal for 6 days or until the patients showed clinical and/or ABG level deterioration. Pulmonary function tests were performed and neuromuscular drive was measured at the beginning and the end of the study. Five of the 11 patients (45.4%) [COPD, 3 patients; and RTD, 2 patients] were reconnected to a ventilator before the scheduled time because of ABG level deterioration. Despite these changes, none of the patients reported severe worsening of symptoms or other medical complications. The patients whose ABG levels worsened had statistically significant decreases in tidal volume and PImax, suggesting that the development of alveolar hypoventilation was related to respiratory muscle weakness. A brief discontinuation of NIMV in patients who were affected by chronic hypercapnic respiratory failure and were well-established on NIMV is associated with a relatively high incidence of ABG level worsening due to the development of alveolar hypoventilation. If NIMV must be briefly interrupted for clinical reasons, the patient should be monitored closely for abrupt worsening, and prompt technical intervention should be provided if a ventilator fails.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.