Abstract
Sir, We read an article by Gupta et al.[1] with keen interest. We wish to express following comments. Paralytic lagophthalmos remains the most serious complication of facial nerve palsy. Temporalis muscle transfer (TMT) for paralytic lagophthalmos, though a dynamic procedure, remains difficult, challenging and time-consuming surgery despite several modifications.[2,3,4] We appreciate the authors for commendable attempt to manage paralytic lagophthalmos by modified silicone sling assisted TMT.[1] Authors[1] mention that the temporalis muscle (TM) is used in dynamic procedures as it is spared in a case of facial palsy that conveys the impression as if TM is innervated by 7th nerve. The fact remains that TM is used because it is innervated by 5th nerve. Authors[1] mention that slings were advanced in the lids between the paralyzed orbicularis oculi and the skin, which in our opinion appears to be superficial. The sling is also visible through the skin. Such a superficial insertion of sling may suffer several disadvantages including extrusion. The silicone sling should have been placed submuscular between orbicularis muscle and the tarsal plate.[2,3] Postoperative day has not been mentioned in the postoperative picture.[1] However, it seems to be early postoperative picture as skin sutures are still intact. Authors[1] have failed to report long-term follow-up results after 3 months. Even postoperative photographs of the palpebral aperture in the primary position and on mastication in early and at 3 months postoperative are not presented. Moreover, authors[1] have failed to document the dynamicity of their procedure. Frey et al.[4] documented dynamic lid closure following TMT using three-dimensional video analysis system. In our opinion, the procedure described by Gupta et al.[1] is hardly any TMT, as the length of muscle shown is quite small, it fails to reach even up to the lateral canthus and is far posterior to the lateral canthus. It appears that TM is mainly acting as muscle stump for just anchoring the silicone rod. Dynamic reanimation of eyelids by TMT has not been achieved using silicone sling. Thus, it does not appear to be a silicone assisted TMT, rather it is more appropriate to call it a TM assisted silicone sling in the eyelid for management of paralytic lagophthalmos. We believe that similar postoperative results can be achieved by passing silicone sling in eyelid as described by Arion.[5] Authors[1] did not comment about postoperative patient's training for chewing exercise. We believe that the patient must be educated about the need to clench the jaw in order to close eyelids voluntarily.[6] Practicing this in front of the mirror is helpful to develop a visual think-blink reflex to achieve dynamic lid closure.[6] As the silicone is a synthetic material, its integration with TM or eyelid tissues is unlikely. Moreover, in long-term with contraction of TM, silicone rod may cut through or lose its elasticity and TM may retract to its original position, resulting in recurrence. Thus, permanency of the procedure seems yet another concern.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.