Abstract

To assess whether more accurate mediastinal lymph nodes radiotherapy can be performed with fluorode oxyglu cosepositron emission tomogaphy/computed tomography. The retrospective study was conducted at Inonu University Medical Faculty, Malatya, Turkey, and Afyon Kocatepe University Medical Faculty, Afyon, Turkey, and comprised record of patients histopathologically diagnosed with non-small cell lung carcinoma and who underwent fluorodeoxyglucose positron emission tomography / computed tomography between January 2013 and December 2016. Surgery and pathology reports of the patients were reviewed. Histopathologically proven malignant and benign lymph nodes were re-identified with fluorodeoxyglucose positron emission tomography / computed tomography imaging. Anatomical and metabolic parameters of lymph nodes were re-assessed by specialists and compared with histopathology reports. Maximum standardised uptake values were used to assess sensitivity, specificity, positive predictive value, and negative predictive values. SPSS 22 was used for data analysis. The study included 144 mediastinal lymph nodes related to 42 patients who had a mean age of 62.4±9.8 years (range: 41-79 years). In terms of subtypes of the primary squamous cell carcinoma was found in 24(57.2%) patients, adenocarcinoma in 12(27.5%), and other subtypes in 6(15.3%) patients. Of the 144 lymph nodes, 48(33.3%) were metastatic. Sensitivity, specificity, positive predictive value, and negative predictive value were 92.8%, 64.3%, 56.9%, and 94.7%, respectively when maximum standardised uptake value >2.5 was used as the malignancy criterion. When lymph node maximum standardised uptake value / liver standardised uptake value-mean>1.69 was used as the criterion, the sensitivity, specificity, positive predictive value, and negative predictive value were 95.83%, 91.67%, 85.2%, and 97.8%, respectively. When the same values with lymph node >8mm was used as the criterion, the four resultant values were 89.6%, 93.8%, 87.8%, and 94.7%, respectively. When lymph node was replaced with mean attenuation >35 as the criterion, the consequent values were 79.2%, 93.8%, 86.4%, and 90.0%, respectively. Lymph node maximum standardised uptake value / liver standardised uptake valuemean> 1.69 was associated with higher negative predictive value and more useful positive predictive value compared to maximum standardised uptake value >2.5. When this parameter was used along with short axis or mean attenuation value, there were no significant increase in positive predictive value, but there was a decrease in negative predictive value.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.