Abstract
Objectives: The objectives of the study were to determine the association of gingival biotype and secondary stability of orthodontic mini-implants using resonance frequency analysis. Materials and Methods: Twenty patients, each receiving two mini-implants, were divided into two groups; thick and thin gingival biotype based on the thickness of gingiva before mini-implant placement. Implant stability was assessed at the time of placement; at the 1st, 2nd, 3rd, and 4th month by resonance frequency analysis. Peri-implant soft-tissue conditions were also examined at each month till 4 months interval using periodontal indices. Results: Thick and thin gingival biotype groups showed statistically different implant stability quotient (ISQ). Mini-implants showing signs of failure consistently displayed lesser ISQ. Statistically significant difference was observed in the scores of peri-implant indices of failure and no failure group of mini-implants. Conclusion: Mini-implants in thin gingival biotype are more susceptible to failure and peri-implantitis compared to thick gingival biotype. Longitudinal assessment of mini-implant stability may help predict failure so as to avoid long duration and cost of orthodontic treatment.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.