Abstract

Recurring combined sewer overflows (CSOs) can have a significant impact on the ecological condition of receiving water bodies. There are several structural measures, like adding retention basins and switching to low impact development solutions, that have been proposed to reduce the number of sewage overflows. Besides, several flow control strategies have been discussed in scientific literature that take advantage of the space within urban drainage networks, which is assumed to be adequate, for temporary storage. The adequacy of such storage space, however, is not a universally valid assumption as a large fraction of drainage networks frequently operate close to their design discharge. In this paper, we investigate the efficacy of flow control for a space-constrained drainage network. We employ a low-cost, heuristic real time control strategy with the use of flow control devices (FCDs) and available in-sewer space to reduce the magnitude of CSOs. We consider the performance of the proposed control strategy and discuss the effect of FCD location on CSO reduction. Our results, based on over 300 rainfall-event simulations, show that the flow control strategy using limited sewer capacity is more efficient during relatively small rainfall events, where the CSO is large enough to enable reduction using the chosen control rules. The CSO is reduced, to varying degrees, for around 80% of rainfall events with peak intensity between 10 and 20 mm h−1. For larger rainfall events, the flow control is more unstable in response to abrupt water release during control operation, which seems to be unavoidable because of the water accumulation effect and the transition to pressurized pipe flow in space-constrained networks. We also found that the flow control performance is highly sensitive to the FCD location – as it depends on the interplay of the peak rainfall intensity and the water level condition immediately upstream of the FCD. The efficacy of a location for flow control is determined by the unfilled capacity (i.e., effective in-sewer storage potential) in the pipe upstream of the FCD during the rainfall peak; furthermore, the location also has to be resistant to the water accumulation effect. Using our analysis, we substantiate two anticipated caveats to flow control strategies when the storage space is limited in a drainage network: diminished performance in CSO reduction and the appearance of additional control-related challenges, which are otherwise mitigated in more spacious networks.

Highlights

  • Unmanaged stormwater discharges have become a potential hazard for urban ecosystems, manifesting as pollution spills into surface water bodies

  • With a better understanding of the parameter setting, we use a single set of flow control devices (FCDs) opening rule parameters and discuss control strategy efficiency based on a large number of rainfall events with different peak intensities and different spatial locations of the FCD

  • We investigated the effect of the FCD location on parameter sensitivity; since FCD-4 and FCD-5 did not show successful flow control cases, the sensitivity analysis was conducted only with FCD-1, FCD-2 and FCD-3

Read more

Summary

Introduction

Unmanaged stormwater discharges have become a potential hazard for urban ecosystems, manifesting as pollution spills into surface water bodies. This increasing risk is caused by the expansion of impervious urban surfaces and the limited hydraulic capacity of drainage systems. This problem is exacerbated by the increasing frequency of extreme rainfall events due to climate change. Excess stormwater may cause urban flooding and an in­ crease of system discharges, creating a threat to local environment Joshi et al (2020) compare and analyze four sustain­ able urban drainage system techniques

Objectives
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call