Abstract

Objective To evaluate the usefulness of measuring the apparent diffusion coefficient (ADC) in diffusion-weighted magnetic resonance imaging to distinguish benign from small, non-necrotic metastatic cervical lymph nodes in patients with head and neck cancers.Materials and MethodsTwenty-six consecutive patients with head and neck cancer underwent diffusion-weighted imaging (b value, 0 and 800 s/mm2) preoperatively between January 2009 and December 2010. Two readers independently measured the ADC values of each cervical lymph node with a minimum-axial diameter of ≥ 5 mm but < 11 mm using manually drawn regions of interest. Necrotic lymph nodes were excluded. Mean ADC values were compared between benign and metastatic lymph nodes after correlating the pathology.ResultsA total of 116 lymph nodes (91 benign and 25 metastatic) from 25 patients were included. Metastatic lymph nodes (mean ± standard deviation [SD], 7.4 ± 1.6 mm) were larger than benign lymph nodes (mean ± SD, 6.6 ± 1.4 mm) (p = 0.018). Mean ADC values for reader 1 were 1.17 ± 0.31 × 10-3 mm2/s for benign and 1.25 ± 0.76 × 10-3 mm2/s for metastatic lymph nodes. Mean ADC values for reader 2 were 1.21 ± 0.46 × 10-3 mm2/s for benign and 1.14 ± 0.34 × 10-3 mm2/s for metastatic lymph nodes. Mean ADC values between benign and metastatic lymph nodes were not significantly different (p = 0.594 for reader 1, 0.463 for reader 2).ConclusionMeasuring mean ADC does not allow differentiating benign from metastatic cervical lymph nodes in patients with head and neck cancer and non-necrotic, small lymph nodes.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call