Abstract
288 Background: D2 surgery is required for clinical T1 gastric cancer with nodal swelling, however, D2 has a higher risk for morbidity than D1/D1+. Moreover, previous study demonstrated that the false positive rate for nodal diagnosis in clinical T1 was very high. To select optimal surgery with high probability, we explored risk factors for false positivity in clinical T1 disease. Methods: Patients who underwent radical gastrectomy for clinical T1 gastric cancer between April 2015 and June 2019 were enrolled. Accuracy, sensitivity, specificity, positive predictive value, and negative predictive values for nodal diagnosis were retrospectively investigated. The risk factors for false positivity were also analyzed by the following factors; age, sex, histological type, tumor size, tumor depth, location, tumor type, presence of ulcer, and timing of CT that is (1) the patients who underwent primary endoscopic mucosal dissection (ESD) but resulted in non-curative resection, then received CT to proceed to surgery (delayed CT group) or (2) the other patients who had received CT before primary surgery or before non-curative ESD (primary CT group). Results: A total of 679 patients were examined in the present study. The accuracy, sensitivity, specificity, positive predictive value, and negative predictive value were 83.5% (567/679), 14.3% (13/91), 94.2% (554/588), 27.7% (13/47), and 87.7% (554/632), respectively. The false positive rate was 72.3% (34/47). In univariate analysis, differentiated tumor ( p= 0.012) and delayed CT (p < 0.001) were associated with the false positivity. Multivariate analysis revealed that delayed CT (OR, 4.534; p < 0.001) was a sole significant risk factor for false positivity. False positive rate was 100% (13/13) in the delayed CT group and 61.8% (21/34) in the primary CT group ( p= 0.009). Conclusions: False positive rate was high in clinical T1 disease, especially when the patients received delayed CT after non-curative ESD. D2 surgery would be unnecessary even though nodal swelling was detected in CT after non-curative ESD.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.