Abstract
After periacetabular osteotomy (PAO), some patients develop osteoarthritis with need of a total hip arthroplasty (THA). We evaluated the outcome of THA following PAO and explored factors associated with inferior cup position and increased polyethylene wear. Follow-up were performed 4 to 10years after THA in 34 patients (38 hips) with previous PAO. Computer analysis evaluated cup position and wear rates. No patient had dislocations or revision surgery. Median scores were: Harris hip 96, Oxford hip 38 and WOMAC 78. Mean cup anteversion and abduction angles were 22o (range 7°–43°) and 45° (range 28°–65°). Outliers of cup abduction were associated with persisting dysplasia (CE <25°). THA after PAO can produce excellent clinical results. Persisting acetabular dysplasia following PAO may lead surgeons to place the acetabular component in excessive cup abduction, and this tendency should be recognized at the time of the PAO.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.