Abstract

AbstractThis paper examines the effect of adsorption of Triclosan (TCS) onto labware on the results obtained during lab-scale experiments. Three sets of experiments were considered; two of them expose the problem in water or wastewater treatability studies and the other one in microbial susceptibility testings. In the former two sets, lab-scale systems; ozonation; and membrane filtration (NF/RO) that are commonly used in water or wastewater treatability studies were utilized and the distribution of TCS within the systems were followed. The ozonation labware tested was composed of a Pyrex reactor with plastic and glass tubings. The NF/RO system was composed of a stainless steel feed tank, a stainless steel membrane unit, stainless steel flanges, and stainless steel and plastic tubings. Ozonation system was operated without ozone gas, but air. Similarly, NF/RO system was without membrane in it. Both of the systems were rinsed with methanol before experiments to remove any possible earlier contamination. Dur...