Abstract

BackgroundThe ‘verification phase’ has emerged as a supplementary procedure to traditional maximal oxygen uptake (VO2max) criteria to confirm that the highest possible VO2 has been attained during a cardiopulmonary exercise test (CPET).ObjectiveTo compare the highest VO2 responses observed in different verification phase procedures with their preceding CPET for confirmation that VO2max was likely attained.MethodsMEDLINE (accessed through PubMed), Web of Science, SPORTDiscus, and Cochrane (accessed through Wiley) were searched for relevant studies that involved apparently healthy adults, VO2max determination by indirect calorimetry, and a CPET on a cycle ergometer or treadmill that incorporated an appended verification phase. RevMan 5.3 software was used to analyze the pooled effect of the CPET and verification phase on the highest mean VO2. Meta-analysis effect size calculations incorporated random-effects assumptions due to the diversity of experimental protocols employed. I2 was calculated to determine the heterogeneity of VO2 responses, and a funnel plot was used to check the risk of bias, within the mean VO2 responses from the primary studies. Subgroup analyses were used to test the moderator effects of sex, cardiorespiratory fitness, exercise modality, CPET protocol, and verification phase protocol.ResultsEighty studies were included in the systematic review (total sample of 1,680 participants; 473 women; age 19–68 yr.; VO2max 3.3 ± 1.4 L/min or 46.9 ± 12.1 mL·kg-1·min-1). The highest mean VO2 values attained in the CPET and verification phase were similar in the 54 studies that were meta-analyzed (mean difference = 0.03 [95% CI = -0.01 to 0.06] L/min, P = 0.15). Furthermore, the difference between the CPET and verification phase was not affected by any of the potential moderators such as verification phase intensity (P = 0.11), type of recovery utilized (P = 0.36), VO2max verification criterion adoption (P = 0.29), same or alternate day verification procedure (P = 0.21), verification-phase duration (P = 0.35), or even according to sex, cardiorespiratory fitness level, exercise modality, and CPET protocol (P = 0.18 to P = 0.71). The funnel plot indicated that there was no significant publication bias.ConclusionsThe verification phase seems a robust procedure to confirm that the highest possible VO2 has been attained during a ramp or continuous step-incremented CPET. However, given the high concordance between the highest mean VO2 achieved in the CPET and verification phase, findings from the current study would question its necessity in all testing circumstances.PROSPERO Registration IDCRD42019123540.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.