Different irradiation protocols are proposed to polymerize dental resins, and discordances remain concerning their impact on the material. To improve this knowledge, we studied entrapment of free radicals in unfilled Bis-GMA/TEGDMA (50:50 wt%) resin after light cure. The tested hypothesis was that various irradiation parameters (curing time, irradiance, and radiant exposure) and different irradiation modes (continuous and pulse-delay) led to different amounts of trapped free radicals. The analysis of cured samples (n = 3) by electron paramagnetic resonance (EPR) revealed that the concentrations of trapped free radicals significantly differed according to the curing protocol. When continuous modes with similar radiant exposure were compared, higher concentrations of trapped free radicals were measured for longer times with lower irradiance. Concerning pulse modes, the delay had no influence on trapped radical concentration. These results give new insights into the understanding of the photopolymerization process and highlight the relevance of using EPR when studying polymerization of dimethacrylate-based materials.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.