Abstract

Yttria-stabilized zirconia (YSZ) is irradiated with 2.0-MeV Au2+ ions and 30-keV He+ ions. Three types of He, Au, Au + He (successively) ion irradiation are performed. The maximum damage level of a sequential dual ion beam implanted sample is smaller than single Au ion implanted sample. A comparable volume swelling is found in a sequential dual ion beam irradiated sample and it is also found in a single Au ion implanted sample. Both effects can be explained by the partial reorganization of the dislocation network into weakly damaged regions in the dual ion beam implanted YSZ. A vacancy-assisted helium trapping/diffusion mechanism in the dual ion beam irradiated condition is discussed. No phase transformation or amorphization behavior happens in all types of ion irradiated YSZ.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.