Abstract

The energetic behavior of two samples of soft magnetic materials fed by inverters has been studied. The authors dealt with the increase of the iron losses due to a nonconventional voltage supply. Six-step and PWM (pulse width modulated) inverter output voltages have been selected as the excitation waveforms for the samples under test. Extensive experimental results of high-quality grain-oriented silicon steel and amorphous-alloy-wound core samples are presented. A detailed description of the testing procedure is shown. The results are quite informative and quantify the iron-loss increase with nonsinusoidal supply in comparison with the results obtained by the standard tests (sinusoidal supply and Epstein method). The comparison can give useful indications to electromagnetic-device designers about the derating factors for the different magnetic materials that have to be used in designing devices fed by static power sources.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.