In this paper, we propose a loss calculation method considering minor hysteresis loops for permanent magnet (PM) motors driven by pulsewidth modulated (PWM) inverters. In the governing equation of the proposed method, both the effects of the major and minor hysteresis phenomena are expressed by a reaction magnetic field. This field is determined by iterative calculations of finite-element analysis (FEA) with a simple hysteresis modeling that considers the minor loops. The proposed method is applied to a PM motor, and the experimental verification is carried out. It is clarified that the minor hysteresis loops affect not only the hysteresis loss but also the eddy current loss because the skin depth varies with the differential permeability of the minor loops.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.