Abstract
The iron loss of doubled-sided linear switch reluctance motor (DLSRM) is analyzed and calculated in this paper. Because of the double salient structure of the switched reluctance motor and the nonlinearity of the magnetization curve of the ferromagnetic material, the flux density waveform is nonsinusoidal. So, it is difficult to calculate the iron loss of DLSRM. This paper mainly introduces the calculation method of dynamic magnetic density of the DLSRM, and basing on this, the simulation model of iron loss of DLSRM is built and compared the iron loss in different parts of the total as a percentage of the motor. Finally, an experimental platform based on DLSRM is built to measure the actual iron loss in the motor and verify the correctness of the calculation of iron loss.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.