Abstract

To evaluate changes in anterior segment anatomy after laser iridotomy for pigment dispersion syndrome. Ultrasound biomicroscopy was performed on 7 eyes of 7 untreated patients with reverse pupillary block and pigment dispersion syndrome. A radially oriented image with the probe perpendicular to the eye in the superior meridian was obtained before and at least 1 week after laser iridotomy in each eye. We assessed changes in angle recess area and iris-lens contact distance. Mean +/- SD patient age was 31.3 +/- 5.7 years and mean +/- SD refractive error was -5.0 +/- 3.9 diopters. Angle recess area (mean +/- SD, 0.78 +/- 0.28 vs 0.35 +/- 0.11 mm2; P=.001, paired t test) and iris-lens contact distance (2.05 +/- 0.28 vs 0.79 +/- 0.13 mm; P<.001) decreased following iridotomy. Central anterior chamber depth did not change. Flattening of the iris following laser iridotomy for pigment dispersion syndrome causes a decrease in iris-lens contact and angle width while lens position remains constant.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.