Abstract

Purpose To describe a novel, entirely ipsilateral femoral technique for distal endograft extension using the Gore Iliac Branch Endoprosthesis. Technique Femoral arterial access is obtained on the side of the intended repair, and a 16F sheath is inserted over a stiff wire. A looped wire is used to pre-cannulate the internal gate of the IBE device prior to insertion, and the device is then positioned and deployed. This through-wire guides access over the IBE flow divider and into the internal gate with a steerable sheath. The internal iliac artery is then selected, and a Viabahn VBX balloon-expandable stent (W.L. Gore, Flagstaff, AZ) is advanced into position and deployed. We present the successful completion of this technique in 4 patients. Conclusion This novel technique allows distal endograft extension with an IBE device using only ipsilateral femoral access and is particularly useful for patients with aneurysmal iliac degeneration in the setting of prior open or endovascular aneurysm repair. This eliminates the need for upper extremity access or contralateral femoral access and navigation across the steep flow divider.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.