Abstract
A closed-form solution is presented for the steady-state response of interior permanent magnet (IPM) synchronous machines to symmetrical short circuits including the effects of q-axis magnetic saturation. Machine response to single-phase asymmetrical short circuits is also investigated. Experimental data are presented to verify predicted behavior for both types of short circuits. It is shown that single-phase asymmetrical short circuit faults produce more severe fault responses with high pulsating torque and a significant threat of rotor demagnetization. A control strategy that purposely transitions such faults into symmetrical three-phase short circuits can minimize the fault severity and associated demagnetization risks. Implications for the design of IPM machines with improved fault tolerance are discussed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.