Abstract
Contrast-enhanced mammography (CEM) is an emerging breast imaging modality. Clinical data is scarce. To summarize clinical evidence on the use of iopromide in CEM for the detection or by systematically analyzing the available literature on efficacy and safety. Systematic review and meta-analysis. Iopromide-specific publications reporting its use in CEM were identified by a systematic search within Bayer's Product Literature Information (PLI) database and by levering a recent review publication. The literature search in PLI was performed up to January 2023. The confirmatory-supporting review publication was based on a MEDLINE/EMBASE + full text search for publications issued between September 2003 and January 2019. Relevant literature was selected based on pre-defined criteria by 2 reviewers. The comparison of CEM vs traditional mammography (XRM) was performed on published results of sensitivity and specificity. Differences in diagnostic parameters were assessed within a meta-analysis. Literature search: A total of 31 studies were identified reporting data on 5194 patients. Thereof, 19 studies on efficacy and 3 studies on safety. Efficacy: in 11 studies comparing iopromide CEM vs XRM, sensitivity was up to 43% higher (range 1%-43%) for CEM. Differences in specificity were found to be in a range of -4% to 46% for CEM compared with XRM. The overall gain in sensitivity for CEM vs XRM was 7% (95% CI [4%, 11%]) with no statistically significant loss in specificity in any study assessed. In most studies, accuracy, positive predictive value, and negative predictive value were found to be in favor of CEM. In 2 studies comparing CEM with breast magnetic resonance imaging (bMRI), both imaging modalities performed either equally well or CEM tended to show better results with respect to sensitivity and specificity. Safety: eight cases of iopromide-related adverse drug reactions were reported in 1022 patients (0.8%). Pertinent literature provides evidence for clinical utility of iopromide in CEM for the detection or confirmation of breast cancer. The overall gain in sensitivity for iopromide CEM vs XRM was 7% with no statistically significant loss in specificity.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.