Abstract

Electronic skins and flexible pressure sensors are important devices for advanced healthcare and intelligent robotics. Sensitivity is a key parameter of flexible pressure sensors. Whereas introducing surface microstructures in a capacitive-type sensor can significantly improve its sensitivity, the signal becomes nonlinear and the pressure response range gets much narrower, significantly limiting the applications of flexible pressure sensors. Here, we designed a pressure sensor that utilizes a nanoscale iontronic interface of an ionic gel layer and a micropillared electrode, for highly linear capacitance-to-pressure response and high sensitivity over a wide pressure range. The micropillars undergo three stages of deformation upon loading: initial contact (0–6 kPa) and structure buckling (6–12 kPa) that exhibit a low and nonlinear response, as well as a post-buckling stage that has a high signal linearity with high sensitivity (33.16 kPa−1) over a broad pressure range of 12–176 kPa. The high linearity lies in the subtle balance between the structure compression and mechanical matching of the two materials at the gel-electrode interface. Our sensor has been applied in pulse detection, plantar pressure mapping, and grasp task of an artificial limb. This work provides a physical insight in achieving linear response through the design of appropriate microstructures and selection of materials with suitable modulus in flexible pressure sensors, which are potentially useful in intelligent robots and health monitoring.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call