Abstract

An available supply of high-specific-activity radioisotopes was identified by the U.S. Department of Energy as a critical priority in the development and eventual deployment of next-generation medical diagnostic and cancer therapy tools. A radioisotope mass separator, located at the Missouri University Research Reactor Center, was developed to provide radioactive ion beams for the separation and production of high-specific-activity lanthanides used in radiopharmacology. Experiments characterizing the ionization efficiency of a thermal ion source supporting the production of high-specific-activity 153Sm are reported. With the goal of maximizing ion current while maintaining beam stability, experiments with the test ion source expand upon previously reported data from a titanium prototype ion source. Experimental results of various factors affecting ion source performance, such as diameter of the extraction orifice, ionizer geometry, ionizer temperature, and sample evaporation rate, are presented.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call