Abstract

The surfaces of nanoscale zerovalent iron (NZVI) used for groundwater remediation must be modified to be mobile in the subsurface for emplacement. Adsorbed polymers and surfactants can electrostatically, sterically, or electrosterically stabilize nanoparticle suspensions in water, but their efficacy will depend on groundwater ionic strength and cation type as well as physical and chemical heterogeneities of the aquifer material. Here, the effect of ionic strength and cation type on the mobility of bare, polymer-, and surfactant-modified NZVI is evaluated in water-saturated sand columns at low particle concentrations where filtration theory is applicable. NZVI surface modifiers include a high molecular weight (MW) (125 kg/mol) poly(methacrylic acid)-b-(methyl methacrylate)-b-(styrene sulfonate) triblock copolymer (PMAA-PMMA-PSS), polyaspartate which is a low MW (2-3 kg/mol) biopolymer, and the surfactant sodium dodecyl benzene sulfonate (SDBS, MW = 348.5 g/mol). Bare NZVI with an apparent zeta-potential of -30 +/- 3 mV was immobile. Polyaspartate-modified nanoiron (MRNIP) with an apparent zeta-potential of -39 +/- 1 mV was mobile at low ionic strengths (< 40 mM for Na+ and < 0.5 mM for Ca2+), and had a critical deposition concentration (CDC) of approximately 770 mM Na+ and approximately 4 mM for Ca2+. SDBS-modified NZVI with a similar apparent zeta-potential (-38.3 +/- 0.9 mV) showed similar behavior (CDC approximately 350 mM for Na+ and approximately 3.5 mM for Ca2+). Triblock copolymer-modified NZVI had the highest apparent zeta-potential (-50 +/- 1.2 mV), the greatest mobility in porous media, and a CDC of approximately 4 M for Na+ and approximately 100s of mM for Ca2+. The high mobility and CDC is attributed to the electrosteric stabilization afforded by the triblock copolymer but not the other modifiers which provide primarily electrostatic stabilization. Thus, electrosteric stabilization provides the best resistance to changing electrolyte conditions likely to be encountered in real groundwater aquifers, and may provide transport distances of 10s to 100s of meters in unconsolidated sandy aquifers at injection velocities used for emplacement.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.