Abstract

The ACIS instrument on-board the Chandra X-ray Observatory (CXO) experienced pronounced degradation in spectrometric performance during the spacecraft's orbital activation and calibration phase. This damage was associated with a sharp increase in charge-transfer inefficiency combined with relatively constant dark current. Damage occurred only during passage through the earth's radiation belts, and only when ACIS remained in the focal plane during the passage. Subsequent measurements and analyses support the conjecture that the damaging radiation entered through the Observatory's High-Resolution Mirror Assembly (HRMA) aperture. A mechanism whereby low-energy magnetospheric protons and heavier ions are scattered through the HRMA and reach the focal plane with just enough energy to stop in the CCD's charge transfer channel provides a reasonably consistent explanation of all observed phenomena. In this paper, we shall describe analyses which support this conclusion. We simulated the mirror surfaces and various path elements using a standard ion transmission code to generate a bi-directional reflectance distribution function (BRDF). We then convolved the BRDF with the geometry using a ray-trace code. This paper presents damage estimates using measured proton fluences and ground measurements of ACIS-type CCD damage versus proton energy and compares them with observed on-orbit damage.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.