A quadrupole mass-spectrometric sampling probe is employed for the study of ion extraction and plasma sheath formation in a discharge plasma of nitrogen at low pressures (9 to 27 μ). The dependence of the specific ion current ratio i(N+)/i(N2+) on the potential of the sampling probe is presented for various pressures and a fixed electron temperature. Kinetic energy distribution curves for individual ionic species are obtained under a variety of conditions of sampling probe potential, pressure, and electron temperature using a retarding potential field applied at the entrance grid of a quadrupole mass filter. Interpretations of the results indicate that ion generation processes and ion-molecule collisions occurring in the sheath may strongly influence the sampling process.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.