Abstract

Experiments to directly bond AlN with Cu were conducted for different pre-treatments of the bonded components. AlN substrates were implanted either with oxygen, or titanium or iron ions at low (15 keV) or high (70 keV) energy, or thermally oxidized. Some Ti-implanted samples were also thermally oxidized. The copper component was annealed and thermally oxidized. The best results, with respect to the bond shear strength, were obtained for low-energy implantation of oxygen and titanium.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.