Abstract

AbstractSpectroscopic investigations of defects are made in alkaline earth oxides implanted with 400 keV Li+ or Na+ ions. Detailed comparisons of ESR, optical absorption, and luminescence spectra confirm that the predominant point defect is the F+ centre. Smaller concentrations of F2 and F centres are also produced. V− centres and isolated anion vacancy centres are not produced by irradiation. Annealing studies demonstrate that colloid centres grow during annealing above 500 K.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.