Abstract
ABSTRACTIon Implantation is emerging as a specialized surface treatment method by which orthopaedic alloys can be doped in order to modify for corrision, fatigue and wear properties.In this paper alterations in the corrosion and fatigue resistance of 316LVM stainless steel and Ti 6A1-4V ELI titanium alloy are considered. The effect of various variables was investigated; ion species, flux, accelerating voltage.Changes in corrosion resistance were monitored by performing anodic polarization studies in deaerated 0.1M NaCi solution at 22°C. The most effective species were found to be tantalum and boron for improvements to stainless steel.Fatigue properties were investigated using a Wohler type rotating bend test. Preliminary results show that nitrogen ion implantation improved the fatigue life for the steel but not the titanium alloy. Indications were found to suggest that time since implantation affect the fatigue properties.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.