Abstract

Ion-exchanger colorimetry for chromium(VI) with 1,5-diphenylcarbohydrazide has been developed for the determination of chromium at μg/l. concentrations in natural water samples. About 90% of the chromium(VI) in a 1-litre sample solution is concentrated in 200–400 mesh Dowex 50W-X4 resin within half an hour. It is possible to obtain higher sensitivity by employing a larger amount of sample solution. Total chromium can be determined by oxidizing chromium(III) to chromium(VI) with ceric sulphate.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.