Abstract

A method based on single column ion chromatography with UV detection was developed for purity testing and assay of monosodium olpadronate. The analyte aqueous solution is precipitated with methanol to enhance the impurities/olpadronate molar ratio, thus improving purity determination at trace levels. The resulting solution is injected into a standard chromatographic system with UV detector in indirect mode with a Waters IC Pak HR column using diluted nitric acid as the mobile phase. The method was fully validated according to ICH guidelines for the determination of phosphite, phosphate, chloride and methanesulfonic acid in olpadronate being suitable for purity testing and assay.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.