Abstract

Ionic current rectification generated by the geometric asymmetry of conical nanochannels has gradually attracted attention, but most studies have been limited to Newtonian fluids. In this study, the ionic current rectification characteristics in conical nanochannels filled with non-Newtonian fluids are investigated by numerical simulations. Electroosmotic flow and ion transport in Sisko fluids are solved using the Poisson-Nernst-Planck equations and the Navier-Stokes equations. The effects of the Debye parameter, power-law indexes and applied voltage on the ionic current, axial potential, ion concentration, radial velocity and rectification ratio in the nanopores are investigated. When κRt = 1, the current rectification ratio increases with the increase of the power-law index. However, when κRt = 6, the current rectification ratio first increases and then decreases with the increase of the power law index, reaching the maximum value at n = 1.0. These findings have positive implications for the construction of some nanodevices such as nanofluidic diodes.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.