Abstract

In present investigation of anionic (fluoride, chloride, bromide, phosphate and sulphate) change in surface and ground water due to industrial effluents by ion chromatography technique has been determined in area of Jammu using Ion-chromatograph (IC-850).Surface and ground water samples were taken before and after discharge of industrial effluents. All required standards for calibration and all the samples (water as well as industrial effluents) have been prepared by using ultra pure water obtained from M Millipore. Both the peak height (PH) and peak area (PA) were used to assess the IC signals. All the peaks for anions were clear with good resolution and there were no interactions between them. The total time for anion analysis was recorded to be about 28 minutes .Anions like fluoride exhibited drastic change in concentration in surface and ground water samples taken after discharge of industrial effluents.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.