Abstract
Iodixanol (Visipaque) 320 mg I/ml, a non-ionic, dimeric, isotonic contrast medium, was compared to ioxaglate (Hexabrix) 320 mg I/ml in cardioangiography. One hundred and two patients with normal renal function were included in the study. The objectives were to evaluate safety, tolerability, radiographic efficacy and effects on renal function. Adverse events, discomfort, vital signs, clinical chemistry parameters, diagnostic information and radiographic density were recorded. Both contrast media had minor effects on the renal function parameters monitored. The patients who received iodixanol experienced fewer adverse events, significantly less discomfort and had a lower increase in heart rate than did the patients in the ioxaglate group. The radiographic efficacy was good in both groups. Iodixanol 320 mg I/ml is safe and effective for use in cardioangiography.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.