Abstract

Three different hospital sites (Oxford, Sutton and Guildford) have performed sampling of their local sewage plant outflow to determine levels of radioactivity resulting from iodine-131 patients undergoing radionuclide therapies. It was found that a maximum of 20% of activity discharged from the hospitals was present in the sewage plant final effluent channel. This is significantly below the level predicted by mathematical models in current use. The results further show that abatement systems to reduce public exposure are unlikely to be warranted at hospital sites.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.