Abstract

This in vitro study evaluated the seal created by varying depths of mineral trioxide aggregate (MTA) plugs placed in an orthograde fashion in five groups of 10 teeth. One group received a 2 mm thick orthograde apical plug of MTA, the second group a 5 mm apical MTA plug, and the third group a 2 mm apical MTA plug with a second 2 mm increment, 24 h later. The remaining portion of the canal in these groups was left unfilled. Group four received a 2 mm MTA plug that set for 24 h and the canal was then back-filled with gutta-percha and eugenol based sealer. Group five was a positive control without an MTA plug. The apical seal was tested using a bacterial leakage model of Actinomyces viscosus. Results showed a statistically significant difference in only the 5 mm apical plug, which completely prevented bacterial leakage.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.