Abstract

We report the development of an electrochemical biosensor platform based on multiplex micro-/nano- electrode arrays toward cancer diagnosis based on rapid profiling of protease activities. Proteases are a large family of enzymes involved in many important biological processes. Quantitative detection of the activity profile of specific target proteases is in high demand for the diagnosis and treatment monitoring of diseases such as cancers. This study demonstrates the fabrication and characterization of a nanoelectrode array platform based on embedded vertically aligned carbon nanofibers for electrochemical detection of protease activities and further development into an individually addressed 3x3 gold thin-film microelectrode array for rapid profiling of multiple protease activities.Peptides with specific sequences of 4 to 8 amino acids are designed and synthesized as the substrates for selective proteolysis by the cognate proteases, which are attached to the electrode surface as the specific probes. The far end is covalently attached with a ferrocene (Fc) group as the redox moiety for electrochemical measurements. The quantity of the intact peptides on the electrode surface can be sensitively detected with an AC voltammetry method and presents as the peak current at the specific potential for Fc oxidation into ferrocenium (Fc+). As the peptide is cleaved by the cognate protease, the peak current decreases exponentially in the continuously repeated AC voltammetry measurements. The recorded kinetic proteolytic curve can be quantitatively described by a surface-based heterogeneous Michaelis-Menten model. The inverse of exponential decay time constant, 1/t, is found to represent the protease activity which equals to [E](kcat /KM), where [E] is the protease concentration and kcat /KM is the specificity constant defined by the kinetic proteolytic reaction constant kcat and the Michaelis equilibrium constant KM. We have systematically investigated the factors that affect the value of kcat /KM, including the peptide sequence, peptide length, temperature and buffer composition, and optimized the conditions for highly sensitive detection of protease activity of cathepsin B, a potential cancer biomarker.Toward rapid profiling of multiple proteases, we have developed a multiplex electrochemical sensor chip based on a 3x3 gold microelectrode array. The nine individual gold microelectrodes are partially buried underneath the surrounding SiO2 thin film, which show highly consistent cyclic voltammetric signals in gold surface cleaning experiments and detecting benchmark redox species in solution. Upon selectively functionalizing the individual gold microelectrodes with the specific ferrocene-labeled peptide probes, simultaneous detection of the proteolytic curves of the target proteases can be obtained over 9 channels by monitoring the decay of the AC voltammetry signal of the ferrocene-labeled peptide molecules. So far, the algorithm for fitting the kinetic proteolytic curves to accurately derive the activity of cathepsin B has been established. Simultaneous detection of the proteolysis of cathepsin B on the microelectrode array functionalized with three different hexapeptides has been demonstrated, showing the potential of this sensor platform for rapid detection of the activity profiles of multiple proteases.Interestingly, the above-discussed electrochemical method detects the activity of the proteases, which reflects the true biological function and is fundamentally different from the concentration derived from commonly used affinity biosensors or assays such as enzyme-linked immunosorbent assay (ELISA). The direct comparison has shown that ELISA measurements will give the same results no matter the original proenzyme form (zymogen) in the sample is activated or not, while the electrochemically measured activity shows dramatic increase after being chemically activated. In addition, in the current practice, each protease is measured separately in its optimal buffer with the pH value varying from 5 to 9. It is not possible to measure them in a common buffer simultaneously. We have demonstrated that the electrochemical method can be applied for protease activity profiling in a buffer at pH = 7.4 that is compatible to the physiology conditions. This enables measuring the activity of multiple proteases in human serum, which is a critical step toward protease activity for cancer diagnosis.The figure shows the optical images of (a) the whole 3x3 Au microelectrode array chip and (b) the active electrode area, and the schematic illustration of (c) the mechanism of proteolysis of the peptide probes, (d) the change of the AC voltammetry signal before and after proteolysis and (e) the kinetic proteolytic curves, i.e. the exponential peak current decay over time, at different protease concentration [E]. Figure 1

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call