We have recently developed a microsystem to electroporate a few cells at the surface of early post-implantation mouse embryos. We could achieve the efficient, reproducible, and safe transfection of various genetic markers, which allowed single cell fate studies during morphogenesis. However, our single-use polymeric device necessitated to be fabricated in a clean room the day before each experiment. Thus, we here introduce an all-glass chip that any biologist can easily recycle in its laboratory. Most importantly, during the technological evolution process we could validate a comprehensive design strategy based on finite element model simulations. Indeed, both the embryo and the microsystem were represented as very simple electric objects and stationary computations enabled to properly predict the voltage pulse amplitude that would yield optimal device performances.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.