Abstract
Lubrication systems have significant effects on the residence time of wear debris (RTWD), which limits the monitoring efficiency of the online debris sensor. The focus of this work is to investigate the relationship between RTWD in lubrication systems and online oil sampling interval. Firstly, a vector representation for the attenuation function of wear debris (AFWD) is introduced in order to depict the removal of wear debris with different sizes. Based on this, a mathematical model is developed to calculate the RTWD. A setting criterion for the online oil sampling interval is also proposed. Thereafter, RTWD in different size ranges was investigated experimentally, in which the concentration of wear debris larger than the micrometer rating of the filter decays to 10% of the initial concentration within 5 min. The results were consistent with the proposed model results. Moreover, we find that the online oil sampling interval must be determined by the residence time of large wear debris caused by abnormal wear. Otherwise, the online distortion monitoring results can result in false conclusions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.