Abstract
We investigated the influence of some critical parameters and operating conditions such as cell temperature, laser intensity, and interrogation technique affecting the performances of a gas cell Cs frequency standard based on coherent population trapping (CPT). Thanks to an original experimental setup, the atoms can be trapped in the dark state and interrogated using continuous wave (CW) or pulsed coherent optical radiations. Using a double-lambda scheme, a signal contrast as high as 52% has been measured in the continuous regime for an optimum cell temperature of 35 degrees C. Compared with the conventional continuous CPT interrogation, the pulsed interrogation technique reduces the light shift by a factor of 300 and allowed it to reach high-frequency stability for higher laser intensities. The frequency stability has been measured to be 9 x 10(-13) for a 1 s integration time. Main noise contributions limiting the short-term and medium-term frequency stability are reviewed and estimated.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.