Abstract

Sound energy distributions and flows within single-space rooms can be exploited to understand the occurrence of multi-slope decays. In this work, a real-size monumental worship space is selected for investigations of non-exponential sound energy decays. Previous field tests in this single-space venue indicate multi-slope formation within such a large volume and the multiple-dome upper structure layout. In order to illuminate/reveal the probable reasons of non-exponential sound energy decays within such an architectural venue, sound energy distributions and energy flows are investigated. Due to its computational efficiency and advantages in spatial energy density and flow vector analysis, a diffusion equation model (DEM) is applied for modeling sound field of the monumental worship space. Preliminary studies indicate good agreement for overall energy decay time estimations among experimental field and DEM results. The energy flow vector and energy distribution analysis indicate the upper central dome-structure to be the potential energy accumulation/ concentration zone, contributing to the later energy decays.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.