Calculations have been made to investigate the energy penetration through the pumping holes of the beam tube at the interaction point of the HERMES experiment at HERA. A shielding screen made from etched nickel foil, pressed into the aluminium of the target cell, was proposed. Several different models were studied. Calculations for the new design of the spring fingers were also made, and the results for the 2000 design are included for comparison. As there have been no measurements as yet, the 2000 values are the only indication of an upper limit of radio frequency interference which is not tolerable for the detector electronics. The effect of discretisation on the results was also analysed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.