Abstract

In the neutronics experiment for the ITER test blanket module with a 6Li-enriched Li 2TiO 3 layer and a beryllium layer conducted at the FNS facility of Japan Atomic Energy Agency, the calculated tritium production rate (TPR) was approximately 10% larger than the measured value only when a neutron source reflector composed of SS316 was attached. On the other hand, the influence of the reflector on the TPR prediction accuracy was not seen in the recent blanket experiment with a natural Li 2TiO 3 layer, beryllium layers and the reflector. We investigated the former experiment in detail, and found an unphysical tendency in the measured TPR distribution. In order to clarify whether the deterioration of the TPR prediction accuracy originates from the reflector or not, we have conducted the same experiment as the previous experiment again. In the present experiment, the measured TPR distribution inside the 6Li-enriched Li 2TiO 3 layer agreed well with the calculated value within an estimated experimental error of 6%. We conclude that the overestimation of TPR observed in the previous experiment would be due to some experimental faults and that the TPR prediction accuracy is good even in the case with the reflector.