Abstract

In this study, the results of simulative and experimental investigations regarding thermal cycling (TC) of a LQFP (Low Profile Quad Flat Exposed Pad) with embedded copper wire bonds are discussed. The focus of this study is to analyze cyclic thermal and mechanical loading at high plastic strain in the heat affected zone (HAZ) above the nail-head, which may lead to fatigue failure of wire bonds in the packages. Thereby, a comparison with multiaxial mechanical test results obtained in a previous study will be drawn [1]. Indeed, the lifetime diagrams for these two methods show a clear correlation. Convincing agreement was found on experimental and on theoretical level. The described accelerated test method can be used as a rapid test for the determination of the lifetimes of wire bonds at various positions on the chip. Moreover, our testing method leads to conclusions, which enable improvements of package design.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.